ECLIPSE

ID #1036

hello when putting position 9 on to clean the contacts, 1. must the unit be in stand by ? 2. when you say disconnect from the amplifier , does this mean just shut off or completely unplug ? if so then why ? please let me know thank you Paul.

please use following instruction from Mr. Paul Letteri, GB.

To clean the contacts in the preamplifier.
1. Make sure the amplifier is off , 2. put preamplifier in standby, turn selector switch – the second switch from the left all the way to the right ,
2. which is ninth position, with volume at zero , you will see the flashing L.E.D lights flashing ,and a clicking sound , this is normal .
3. Proceed to do this for ten minutes once a week.
The cleaning option is available through the selector switch only.

Thank you Paul